Grades and Physical Properties Chart - Mechanical, Structural and Tribological Applications
          A R L E N   Remarks    
        A/G
(For
Series
mechanical
-
and_structural
-
parts)
-A/E
(For
Series
tribolic

0
applications)

     
      Test method         non-
reinforced
non- reinforced,
flameretardant
       
Physical Properties   Unit ASTM A315 A335 A350 G335 AE4200 AE4200N AE2230 PA66 PA MXD6 PPS
Glass fiber content   % - 15 35 50 35 0 0 30 30 40 40
Specific gravity   - D792 1.30 1.48 1.63 1.47 1.10 1.40 1.37 1.37 1.53 1.67
                           
Mechanical Properties                           
Tensile strength dry MPa D638 120 240 300 200 80*3 70*3 200 180 220 170
  (moist)*¹     (110) (220) (270) (180) (70)*3 (60)*3 (180) (130) (150) (-)
Tensile elongation dry % D638*² 3 3 3 3 50*3 4*3 4 4 2 2
  (moist)*¹     (3) (3) (3) (3) (50)*3 (4)*3 (4) (4) (2) (-)
Flexural strength dry MPa D790 190 360 430 340 110 120 270 260 310 250
  (moist)*¹     (170) (320) (390) (310) (100) (110) (240) (180) (210) (-)
Flexural modulus dry MPa D790 6,000 12,000 17,000 11,000 2,400 3,000 9,000 8,800 13,000 13,000
  (moist)*¹     (5500) (11,000) (15,000) (10,000) (2,200) (2,700) (8,000) (6,000) (11,000) (-)
Izod impact strength dry J/m D256 50 130 150 100 200 70 100 130 80 80
(notched) (moist)*¹     (70) (150) (160) (120) (220) (80) (110) (150) (80) (-)
Rockwell hardness   M scale D785 105 110 110 - 65
(R110)
80 95 95 95 100
                           
Thermal Properties                          
Melting point   °C - 320 320 320 300 320 320 320 260 240 280
Glass transition point   °C - 125 125 125 140 125 125 125 50 80 90
Deflection temp. under load (1.82MPa)   °C D648 290 310 310 280 135 145 300 255 230 265
Coefficient of linear
thermal expansion
Flow direction
Vertical direction
X10-5/°C D696 3.4
5.5
2.0
4.5
1.8
4.2
-
-
8.0
8.2
6.5
6.7
2.6
6.0
2.2
9.0
2.0
4.5
2.0
4.0
           -                
Electrical Properties                           
Volume resistivity (dry) • cm D257 1016 1016 1016 1016 1016 1015 1016 1015 1016 1016
Dielectric constant
(106 Hz)
(dry) - D150 4.2 4.5 4.5 - 3.3 3.3 3.7 3.3 4.0 3.8
Dielectric dissipation factor
(106 Hz)
(dry) - D150 0.020 0.018 0.018 - 0.018 0.014 0.018 0.015 0.009 0.0014
Dielectric breakdown
voltage
(dry) kV/mm D149 25 27 29 28 23 31 27 23 31 17
                           
Other Properties                          
Mold shrinkage
(2mmt)
Flow direction
Vertical direction
% D955 0.5
0.6
0.3
0.6
0.2
0.6
0.2
0.5
0.9
0.9
0.8
1.0
0.4
0.7
0.4
0.8
0.2
0.6
0.2
0.4
Water absorption
(24 hr in water)
(2mmt)
23°C

100°C
%

%
D570 0.4

2.5
0.3

1.8
0.2

1.2
0.3

1.7
0.4

2.6
0.3

2.0
0.2

1.7
0.8

4.5
0.2

3.2
0.02

0.3
Flammability   - UL94 H B H B HBequiv. HBequiv. H B V-0 HBequiv. H B H B V-0
000000000000000000000000 0000000000000000 00000000000                      

Notes:
The above figures are just representative values but not specification values.
*1 Moist: In a saturated state in the atmosphere at 23°C and a relative humidity of 65%
*2 Elongation was measured between the chucks.
*3 Test specimens of the non-reinforced grades were 2 mmt.

Unit conversion:
Tensile strength, flexural strength,
flexural modulus.
1 Mpa = 10.2 kg/cm²
Izod impact strength.
1 J/m=0.102 kg • cm/cm