| A | R | L | E | N | Remarks | ||||||||
| C series | (For | electrical | and | electronic | parts) | ||||||||
| Test method | flame- retardant |
flame- retardant |
flame- retardant |
flame- retardant |
flame- retardant |
flame- retardant |
flame- retardant |
||||||
| Physical Properties | Unit | ASTM | C215 | C230 | C240 | C230N | C240N | CH230N | CH245NK | PA46 | PPS | LCP | |
| Glass fiber content | % | - | 15 | 30 | 40 | 30 | 40 | 30 | 45 | 30 | 40 | 30 | |
| Specific gravity | - | D792 | 1.30 | 1.42 | 1.53 | 1.72 | 1.75 | 1.63 | 1.77 | 1.68 | 1.67 | 1.62 | |
| Mechanical Properties | |||||||||||||
| Tensile strength | dry | MPa | D638 | 110 | 170 | 210 | 170 | 180 | 160 | 160 | 160 | 170 | 140 |
| (moist)*¹ | (90) | (140) | (180) | (140) | (150) | (140) | (140) | (12.0) | (-) | (-) | |||
| Tensile elongation | dry | % | D638*² | 3 | 3 | 3 | 3 | 3 | 4 | 3 | 4 | 2 | 3 |
| (moist)*¹ | (3) | (3) | (3) | (3) | (3) | (3) | (3) | (4) | (-) | (-) | |||
| Flexural strength | dry | MPa | D790 | 180 | 260 | 300 | 260 | 280 | 240 | 250 | 250 | 250 | 220 |
| (moist)*¹ | (150) | (220) | (260) | (220) | (240) | (200) | (210) | (190) | (-) | (-) | |||
| Flexural modulus | dry | MPa | D790 | 6,000 | 10,000 | 13,000 | 12,000 | 13,000 | 11,000 | 14,000 | 10,000 | 13,000 | 13,000 |
| (moist)*¹ | (4,000) | (7,000) | (9,000) | (8,500) | (9,000) | (8,000) | (10,000) | (7,500) | (-) | (-) | |||
| Izod
Impact strength (notched) |
dry (moist)*1 |
J/m |
D256 |
50 (55) |
80 (90) |
85 (90) |
70 (80) |
75 (80) |
80 (90) |
90 (100) |
80 (100) |
80 (-) |
110 (-) |
| Rockwell hardness | M scale | D 785 | 105 | 110 | 110 | 110 | 110 | 95 | 95 | - | 100 | - | |
| Thermal Properties | |||||||||||||
| Melting point | °C | - | 310 | 310 | 310 | 310 | 310 | 310 | 310 | 295 | 280 | - | |
| Glass transition point | °C | - | 85 | 85 | 85 | 85 | 85 | 85 | 85 | 60 | 90 | - | |
| Deflection
temp. under load (1.82MPa) |
°C | D648 | 295 | 300 | 300 | 295 | 295 | 290 | 290 | 285 | 265 | 280 | |
| Coefficient
of linear thermal expansion |
Flow
direction Vertical direction |
X10-5/°C | D696 | 3.4 5.5 |
2.4 5.0 |
2.0 4.5 |
2.4 5.0 |
2.0 4.5 |
3.0 6.0 |
2.5 5.5 |
- - |
2.0 |
- - |
| Electrical Properties | |||||||||||||
| Volume resistivity | (dry) | D257 | 1016 | 1016 | 1016 | 1015 | 1015 | 1015 | 1015 | 1015 | 1016 | 1016 | |
| Dielectric
constant (106 Hz) |
(dry) | - | D150 | 4.2 | 4.5 | 4.5 | 3.9 | 4.0 | 4.0 | 4.3 | 3.8 | 3.8 | 4.0 |
| Dielectric
dissipation factor (106 Hz) |
(dry) | - | D150 | 0.020 | 0.018 | 0.018 | 0.012 | 0.011 | 0.013 | 0.011 | - | 0.0014 | - |
| Dielectric
breakdown voltage |
(dry) | kV/mm | D149 | 25 | 28 | 30 | 20 | 22 | 25 | 22 | - | 17 | - |
| Other Properties | |||||||||||||
| Mold
shrinkage (2mmt) |
Flow
direction Vertical direction |
% | D955 | 0.6 0.9 |
0.5 0.8 |
0.4 0.8 |
0.4 0.8 |
0.3 0.7 |
0.4 0.8 |
0.3 0.7 |
- - |
0.2 0.4 |
- - |
| Water
absorption (24 hr in water) (2mmt) |
23°C 100°C |
% % |
D570 | 0.4 3.8 |
0.3 3.0 |
0.2 2.8 |
0.3 3.0 |
0.2 2.8 |
0.3 3.0 |
0.2 2.8 |
0.8 4.7 |
0.02 0.3 |
0.02 0.06 |
| Flammability | - | UL94 | H B | H B | H B | V-0 | V-0 | V-0 | V-0 | V-0 | V-0 | V-0 | |
| 0000000000000000000000 | 00000000000000000 |
|
Notes: |
Unit
conversion: Tensile strength, flexural strength, flexural modulus. 1 Mpa = 10.2 kg/cm² |
Izod
impact strength. 1 J/m=0.102 kg cm/cm |